SZ - Chemical Centrifugal Pumps with Fluoroplastic Flow Passage

Menu
SZ - Chemical Centrifugal Pumps with Fluoroplastic Flow Passage

Description and characteristics of SZ chemical centrifugal pumps

A single block centrifugal single-stage electric pump with axial inlet and radial outlet. The wet ends are made of F26(F46) ftoroplast, casing parts - of cast iron, impeller - steel-reinforced. The inlet and outlet nozzles are connected to a pipeline via standard flanges.

Design features

  • SZ electric pump - a single block centrifugal single-stage electric pump with axial inlet and radial outlet.
  • The wet ends are made of F26(F46) ftoroplast, casing parts - of cast iron, impeller - steel-reinforced
  • The inlet and outlet nozzles are connected to a pipeline via standard flanges.

Characteristics

  • Capacity: Up to 18,5kWt
  • Pressure: Up to 284m
  • Flow rate: Up to 240m3/hour
  • Price:From 1220$
Order
Read More...

Explanation of characteristics

  • The hydraulic characteristics are according to ISO9906
  • Doagrams are given for motor constant speed of 2900 rpm, at water test with a temperature of 20оС, kinematic viscosity of 1mm2/s, (1cSt), with water free of air bubbles
  • H/Q – dependence of head on capacity diagram with the nominal speed
  • P2/Q – dependence of input power on supply diagram if liquid density is х103kg/m3
  • Eta/Q – efficiency diagram determining electric pump effective operation
  • NPSH/Q – allowable suction head diagram
  • The electric pumps shall be used within the operational range specified in the specification chart to exclude the increased wear at high heads and motor overtemperature at overfeedings
  • When pumping liquid with a density over 1350 kg/m3, a motor of higher capacity shall be used.

Motor

  • Squirrel-cage induction motor
  • IP rating: IP55
  • Insulation class: F
  • Standard voltage: 3Х380 V, 50 Hz

Installation

  • During installing it is required to ensure that pipeline weight does not affect the electric pump
  • The electric pump shall be fastened properly on horizontal surface
  • For normal operation of the electric pump, it shall be installed in a non-freeze, well ventilated area
  • Electric protection devices shall protect the pump against damages related to zero phase, non-constant voltage, short circuit, overload.

Operation conditions

  • Pure liquid without abrasive contaminants and fibers
  • Fluid temperature: -20о С to +120оС
  • Liquid density: max 1350 kg/m3
  • Pump body pressure: max 10 Bar
  • Ambient temperature: max +40оС
  • Altitude elevation: max 1000 m.

Application of SZ chemical centrifugal pumps

  • Pumping of chemically active and neutral liquids: acids of various concentration, alkalies, brines, oxidizing agents, organic solvents, galvanic mixtures, toxic chemicals, paints, varnishes, and etc.
  • It is used in chemical, food, electrotechnical, printing and other industries.

Symbolic notation

Symbolic notation - SZ - Chemical centrifugal pumps